Advisory...
It has recently come to our attention that the Spindle Inlet cable on the Onefinity Elite's Masso controller needs a minor modification in order to make CCW functional
With your Elite machine turned off... Open your Masso Touch controller by loosening these 4 screws:
The controller's face will open up like a book:
On some machines, Onefinity has wired in their blue wire into pin 7 while others have both the blue and white wire tapped off.
Before:
What you'll want in order to make CCW fully functional with PwnCNC Spindle and ATC Systems, you should remove the blue wire going into pin 7 (if one exists) tape it off... and instead put the white wire into pin 7 like this:
After:
Additional Information:
GX12 6-pin spindle connector details:
GX12 Pin 1 = Black = Ground and wired into one of the black ground connectors on the masso.
GX12 Pin 2 = Red = PWM and wired into Spindle Control pin 1
GX12 Pin 3 = Yellow = CW or Digital Input #1 and wired into Spindle Control pin 5
GX12 Pin 4 = Green = Digital Common which gets wired into Spindle Control pin 4 and jumpered over to pin 6
GX12 Pin 5 = White = CCW or Digital Input #2 and should be wired into Spindle Control Pin 7
GX12 Pin 6 = Blue = 10v Power should be tapped off as the G3 does not need this wire to control the vfd.
Note that there is a second blue wire hooked up to Spindle Control Pin 2. If you traced this you'll find it leads down to one of the large molex connectors on the back of your controller. This wire makes its way down to the power supply that provides you with a 110v outlet for controlling a palm router.